Feature
High safety factor: the emergency stop button is designed on the right side of the equipment, and a protective cover is added to avoid accidentally touching the device.
Humanized design: the shape is simple and compact, it can be hung on the wall and erected, and it can resist cold, moisture and heat, so it is suitable for all kinds of environments of building stations.
Good operation efficiency: efficient heat dissipation, stable operation, modular design and easy maintenance.
Strong compatibility: intelligent and efficient, stable operation, national standard interface and protocol, compatible with all electric vehicle charging.
Detail
EV type2 AC chargers are available in wall-mounted and floor mountedtypes with output current in 16A,32A and 63A(dual guns). The chargeris reliable, flexible, fast and easy to operate. It is fully tested by author-ities, suitable for public and residential parking lots, highway serviceareas, etc.
Elegant design
2 charge points
Preconfigured and ready to install
Integrated temperature monitoring
Weatherproof
Low stand-by energy consumption
Parameter
Item |
Tech index |
||||||
Input |
Rated Input voltage (V) |
AC230/400V |
|||||
Rated input frequency(Hz) |
50/60Hz |
||||||
AC power connection |
3P+N+PE |
||||||
Output |
Output voltage (V) |
AC230/400V |
|||||
Output current (A) |
16A (3phase) |
16A+16A (3phase) |
32A (3phase) |
32A+32A (3phase) |
63A (3phase) |
63A+63A (3phase) |
|
Output power |
11kW (one gun) |
22kW (dual guns) |
22kW (one gun) |
44kW (dual guns) |
44kW (No gun) |
80kW (dual guns) |
|
Environ mental |
Charging interfaces |
1or2 |
|||||
Communication Interface |
Ethernet |
||||||
Operating Temperature (℃) |
-20 to 50 |
||||||
Storage Ternperature (℃) |
-40 to 70 |
||||||
Humidity (%) |
5 - 95 (non-condensing) |
||||||
Above sea level(m) |
≤2000 |
||||||
Cable length |
3.5m |
||||||
Environment |
No acid, alkaline or other corrosive gases or explosive gases in the ambient air, rain and snow prevention measures required |
||||||
General |
IP level |
IP55 |
|||||
Electric meter |
MID (Measuring Instruments Directive) |
||||||
HMI |
Glare-free 4.3-inch touch screen, Display of the charging process |
||||||
User Authentication |
RFID |
||||||
Protections |
Over-current, Over-voltage, under voltage, leakage, anti-lightning, emergency stop, pull -out to power-or,full autostop |
||||||
Installation |
Wall-mounted or floor-mounted |
||||||
Dimensions (HxWxD,mm) |
600*450*203 |
||||||
Conformity and safety |
CE |
||||||
Standards |
EC 62196 Mode 3 type 2, |
Service & Support
-With
specialized after-sales service agencies, providing telephone support, on-site
service, return and repair service, etc.
-With
user information database, which can inquire the device configuration,
operation, maintenance, quality, service and all the dynamic information,
providing reliable technical support.
Support
hotline:0086-0592-6882290
Email: export@xmnewyea.com
Xiamen
Newyea Science and Technology Co.,Ltd.
Add.:11F,
Hesheng Building No.8 ,Jinshan Road, Siming District Xiamen,China
Small and medium-sized power wireless power supply, Big power wireless power supply, Microwave power supply